UL PRODUCT CATEGORY

Assembly Usage Disclaimer

Roof Deck Constructions


See General Information for Roof Deck Constructions

Construction No. 506

April 02, 2019

Uplift — Class 90

Fire Not Investigated

    1. Metal Roof Deck Panels* — No. 24 MSG min thick coated steel. Panel width, max 18 in., min 12 in.; rib height 2 in. Panels continuous over two or more spans. The panel flat area may have optional striations or minor corrugations placed at various locations in the panel flat area beginning min of 2 in. from side ribs. The upper flange of the panel rib may be horizontal, or optionally formed down to form an angle of 0 degree to 90 degree between the vertical segment and the top flange of the rib. End lap to occur adjacent to and within 12 in. of purlin (Item 6) with panels overlapped 2 in. min.

    An end lap back-up-plate (Item 2A) to be used. A bead of sealant may be used at panel end laps and side ribs. Ribs to be seamed with an electric or hand seaming tool to form a flange with a tight hem. Seaming process to include the upper portion of the Panel Clips (Item 2).

    ACI BUILDING SYSTEMS INC (View Classification)"UltraLok", "UltraLok 216", "UltraLok 218"


    ALLIANCE STEEL INC (View Classification)"Alliance Lok 212", "Alliance Lok 216", "Alliance Lok 218"


    ALLSOUTH PRE-ENGINEERED COMPONENTS L L C (View Classification)"APEC 216", "APEC 218"


    BEHLEN MFG CO (View Classification)"ZL-16"


    BIGBEE STEEL BUILDINGS INC (View Classification)"Bigbee VR"


    CENTRAL STATES MFG INC (View Classification)"Central Span"


    CENTRIA, A DIVISION OF NCI GROUP, INC (View Classification)"SDP200-12", "SDP200-16", "SDP200-18"


    HORIZON STRUCTURAL SYSTEMS (View Classification)"Panel Craft"


    MCELROY METAL MILL INC (View Classification)"Maxima-212", "Maxima-216", "Maxima-218"


    METAL SALES MANUFACTURING CORPORATION (View Classification)"Magna-Loc 18", "Magna-Loc 16" or "Magna-Loc 180" (180° Seam)


    MBCI (View Classification) "BattenLok HS"


    RIGID GLOBAL BUILDINGS L L C (View Classification) "Platinum Series"


    ROLLFAB METAL BUILDING PRODUCTS (View Classification)"MS-200HP/90" or "MS-200HP/180"


    SCHULTE BUILDING SYSTEMS INC (View Classification)"VS-216"


    SOUTHEASTERN METALS MANUFACTURING CO INC (View Classification)"Rock-Lok"


    STANDARD STRUCTURES INC (View Classification)"PanelCraft"


    TAYLOR METAL INC, DBA TAYLOR METAL PRODUCTS (View Classification)"MS200"


    TRIAD CORRUGATED METALS INC (View Classification)"MS216" or "MS218"


    TREMCO INC"TremLock VP212", "TremLock VP216", "TremLock VP218"


    WHIRLWIND STEEL BUILDINGS INC (View Classification)"WeatherLok-16"


    1A. Metal Roof Deck Panels* — (Not Shown) - Panels (coated steel only) may be physically or mechanically curved at a radius of 4 ft. or greater.

    MCELROY METAL MILL INC Maxima ADV


    TREMCO INCTremLock VP180


    2. Roof Deck Fasteners* (Panel Clips) — Located at side of panels over purlins (Item 6). (Max spacing 60 in. OC). When wood thermal block (Item 4A) is used, clips to be located on top. Either of the following:
    Fixed Clip — (Not Shown) — One piece assembly fabricated from No. 22 MSG min thick steel, 3-1/2 in. wide.

    BUILDING RESEARCH SYSTEMS INC (View Classification)"Challenger 100 Fixed Clip"


    MCELROY METAL MILL INC (View Classification)"Maxima Fixed Clip"


    Floating Clip — Two piece assembly with a base fabricated from No. 16 MSG min thick steel, 2 in. wide and a top fabricated from No. 22 MSG min thick steel, 4-5/16 in. wide.

    BUILDING RESEARCH SYSTEMS INC (View Classification)"Challenger 100 Floating Clip" or "MPW-1213-XX Floating Clip".


    MCELROY METAL MILL INC (View Classification)"Maximum Floating Clip"


    Floating Clip— Two piece assembly with a base fabricated from No. 16 MSG min thick steel, 3-3/8 in. wide and a top fabricated from No. 22 MSG min thick steel, 4-5/16 in. wide.

    BUILDING RESEARCH SYSTEMS INC (View Classification)"MPS-PC Floating Clip"


    2A. End Lap Back-Up-Plate — (Not shown) — No. 16 MSG min thick coated steel channel, 3 in. wide with two 3/8 in. deep legs. Max length 74 in. Located under the panel end lap (50 ksi min yield strength).
    2B. Roof Deck Fasteners*(Cinch Plate) — (Optional) — (Not Shown) — width 1-5/16 in., length 18 in. max. Fabricated from No. 20 MSG min thick stainless steel. Located over end lap.

    BUILDING RESEARCH SYSTEMS INC (View Classification)"PC-16 Cinch Plate", "PC-18 Cinch Plate"


    2C. End Lap Back-Up-Plate — (Optional) — (Not shown) — No. 16 MSG min thick coated steel. Width 11, 15 or 17 in., length 7 in. Two 3/4 in. by 3/4 in. tabs and a 1 in. deep vertical leg located at upslope edge of panel. Used with Item 2A when Item 2B is not used (50 ksi min yield strength).
    3. Fasteners (Screws) — For panel clip-to-purlin attachment to be No. 1/4-14 by min 1 in. long self drilling, self-tapping hex-washer-head plated steel screws. Two fasteners used per clip. Fasteners used at end lap to be one of the following: No. 1/4-14 by 1 in. long Type AB point, self-drilling, self-tapping hex-washer-head plated or stainless steel screws or No. 12-14 by 1-1/4 in. long self-drilling self-tapping hex-washer-head plated steel screws. Spacing for 16 in. wide panels to be a 1, 3, 4, 4, 3 in. pattern; spacing for 18 in. wide panels to be a 1-1/2, 3-1/2, 4, 4, 3-1/2, 1-1/2 in. pattern. When optional cinch plate (Item 2B) is used, four fasteners to be required, inserted into factory punched guide holes.
    4. Thermal Spacer — (Optional) — Polyisocyanurate — 3/8 in. min, 2-3/8 in. max thick, 4 in. min width, length sized to fit between panel clips (Item 2).
    4A. Thermal Block — (Optional) — Nom 2 by 4 in. wood, length continuous.
    5. Insulation — (Optional) — Any compressible blanket insulation 8 in. max thick before compression, or 6 in. max thick when located between Thermal Spacer (Item 4) or Thermal Block (Item 4A) and purlin (Item 6).
    6. Purlins — No. 16 MSG min thick steel ( 50 ksi min yield strength ). Max spacing 60 in. OC.

    Refer to General Information, Roof Deck Constructions for items not evaluated.

    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2019-04-02
TGKX.506 506 TGKX 997005001 CONSTRUCTION Active 20190402 20190402 201077001 121975001 100584108 225291001 347953002 157261001 128669004 100576058 513628001 997005001 139289001 100570336 100512980 100604030 267337002 158538001 664740001 100574142 718947007 160466001 513628001 718947007 253116001 513628001 253116001 513628001 253116001 253116001

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".