UL PRODUCT CATEGORY

Assembly Usage Disclaimer

Roof Deck Constructions


See General Information for Roof Deck Constructions

Construction No. 39

November 08, 2018

Uplift — Class 90

Fire Not Investigated

    1. Metal Roof Deck Panels* — No. 26 MSG min gauge coated steel. Panels continuous over two or more spans. End laps to occur over purlins with panels overlapped 6 in. with lap beginning 1 in. from edge of purlin flange and extending across purlin. A bead of sealant may be used at panel end and side laps.

    ACI BUILDING SYSTEMS INC (View Classification) — "M" or "PBM"


    ALLIANCE STEEL INC (View Classification) — "Alliance M"


    ALLSOUTH PRE-ENGINEERED COMPONENTS L L C (View Classification) — "U" or "PBU" Panel


    AMERICAN BUILDINGS CO (View Classification) — "Multi-Rib".


    BERRIDGE MFG CO (View Classification) — Type "M"


    BUILDING COMPONENTS INC (View Classification) — "U-Panel"


    BBM STEEL BUILDINGS INC (View Classification) — "M-Panel"


    CENTRAL STATES MFG INC (View Classification) — "M-Loc"


    CENTRAL TEXAS METAL ROLLFORMING INC (View Classification) — "U-Panel"


    CORLE BUILDING SYSTEMS INC (View Classification) — "R Panel"


    DEAN STEEL BUILDINGS INC (View Classification) — "RIB-6"


    EAST TEXAS ARCHITECTURAL SHEETMETAL L L C, DBA ETAS INC (View Classification) — Type "U" or "PBU"


    JNL STEEL COMPONENTS INC (View Classification) — Type "U-PANEL" or "PBU-PANEL"


    MBCI (View Classification) — Type "U" or "PBU"


    MCELROY METAL MILL INC (View Classification) — "U" or "PBR"


    METAL PANELS INC (View Classification) — "Strongseam M Panel"


    METAL SALES MANUFACTURING CORPORATION (View Classification) — Type "U" or "PBU"


    MUELLER INC (View Classification) — "PBU" or "UPN" or "U"


    NCI BUILDING SYSTEMS L P (View Classification) — Type "U" or "PBU"


    SAN ANTONIO QUALITY METALS (View Classification) — Type "U" or "PBU"


    SCHULTE BUILDING SYSTEMS INC (View Classification) — "U" or "PBU" Panel


    SOUTHWEST METAL COMPONENTS AND SUPPLY LP (View Classification) — "U-Panel" or "PBU"


    TERRY BUILDING CO INC (View Classification) — "M" Panel


    TEXAS BUILDING AND ROOFING SUPPLIES INC — "U" or "PBU" Panel


    TREMCO INC — "TremLock "U" Panel"


    TSB INDUSTRIAL INC (View Classification) — "U/M" Panel


    WEST TEXAS STEEL & SUPPLY (View Classification) — Type "U" or "PBU"


    WHIRLWIND STEEL BUILDINGS INC (View Classification) — "Lo-Rib".


    2. Panel Fasteners — For panel to purlin and panel to panel connections to be No. 14 self-tapping, hex-head, plated steel or stainless steel screws with a separate 5/8 in. O.D. steel or aluminum washer and a separate neoprene sealing washer. Length: For panel to purlin fasteners to be 3/4 in. for insulation up to 3 in. and 1-1/4 in. for insulation over 3 in. For panel to panel fasteners to be 3/4 in.

    Spacing for panel to purlin fasteners to be 6 in. O.C. with fasteners located adjacent to the major ribs.

    Pilot holes: For panel to purlin fasteners to be 13/64 in. diam.

    For panel to panel fasteners to be 1/8 in. diam.

    At end laps spacing to be 6 in. O.C. with fasteners located adjacent to major ribs.

    Spacing for panel to panel fasteners to be 12 in. O.C.

    Pilot holes: For panel to purlin fasteners to be 13/64 in. diam.

    For panel to panel fasteners to be 1/8 in. diam.

    As An Alternate Fastener — No. 12-14 self-drilling, self-tapping, 1/2 in. hex-washer head Type B steel or stainless steel screws with a neoprene sealing washer may be used. Length: For panel to purlin fasteners to be 1 in. for insulation up to 3 in. and 1-1/2 in. for insulation over 3 in. For panel to panel fasteners to be 1 in. Spacing to be the same.
    3. Insulation — (Optional) — Any compressible blanket insulation 4 in. max thickness before compression.
    4. Purlins — No. 16 MSG min gauge steel (55,000 psi min yield strength). Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for Items not evaluated.

    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2018-11-08
TGKX.39 39 TGKX P1557786 CONSTRUCTION Active 20181108 20181108 201077001 121975001 100584108 189626001 768707001 920304001 100579824 157261001 960510002 676209002 307581001 100057479 100556627 139289001 513628001 771337001 997005001 700707001 901683001 100560333 100604030 105578001 100607781 100535089 718947007 P1557786 P2227950 160466001

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".