November 08, 2018

Uplift — Class 90

Fire Not Investigated

    1. Metal Roof Deck Panels* — No. 26 MSG minimum gauge coated steel. Panels continuous over two or more spans. End laps to occur over purlins with panels overlapped 3 in. minimum, 6 in. maximum with laps beginning even with purlin web and extending across purlin flange. A bead of sealant may be used at panel side and end laps.

    A & S BUILDING SYSTEMS L P (View Classification) — "R" or "PBR" Panel


    ACI BUILDING SYSTEMS INC (View Classification) — "R" or "PBR Panel"


    ALL STEEL BUILDINGS & COMPONENTS TUBULAR DIVISION INC (View Classification) — "R or PBR panel"


    ALLIANCE STEEL INC (View Classification) — "Alliance PBR"


    ALLSOUTH PRE-ENGINEERED COMPONENTS L L C (View Classification) — "R" or "PBR" Panel


    AMERICAN BUILDING COMPONENTS (View Classification) — "R or PBR Panel"


    AMERICAN BUILDINGS CO (View Classification) — Long Span III


    B C STEEL BUILDINGS INC (View Classification) — "R/PBR"


    BIGBEE STEEL BUILDINGS INC (View Classification) — "Bigbee-RibII"


    BORGA STEEL INC (View Classification) — "BSP"


    BRIDGER STEEL (View Classification) — "PBR Panel"


    BUILDING COMPONENTS INC (View Classification) — "R-PANEL" or "PBR-PANEL"


    BURROW CONSTRUCTION INC (View Classification) — "R Panel"


    BBM STEEL BUILDINGS INC (View Classification) — "R-Panel"


    CENTRAL STATES MFG INC (View Classification) — "R-Loc"


    CENTRAL TEXAS METAL ROLLFORMING INC (View Classification) — "R-Panel"


    CO BUILDING SYSTEMS (View Classification) — "R" or "PBR"


    CORLE BUILDING SYSTEMS INC (View Classification) — "R Panel"


    CREGO METAL SYSTEMS (View Classification) — "CMR"


    DAKOTA STEEL & TRIM INC (View Classification) — "R Panel"


    EAST TEXAS ARCHITECTURAL SHEETMETAL L L C, DBA ETAS INC (View Classification) — "R Panel"


    FLATIRON STEEL (View Classification) — "PBR"


    FLEXOSPAN STEEL BUILDINGS INC (View Classification) — "R" Panel


    H&H METAL PRODUCTS INC (View Classification) — "PBR Panel"


    GIDEON STEEL PANEL CO L L C (View Classification) — "Gideon R-Panel" or "Gideon PBR"


    HORIZON STRUCTURAL SYSTEMS (View Classification) — "R" or "PBR"


    IDEAL STEEL L L C (View Classification) — "PBR Panel"


    INDACO METALS L L C (View Classification) — "Indaco R" or "Indaco PBR"


    JAG METALS LLC (View Classification) — "PBR Panel"


    JNL STEEL COMPONENTS INC (View Classification) — "R-PANEL" or "PBR-PANEL"


    JOHN FLANERY DBA METAL COUNTRY (View Classification) — "R-Panel"


    KIRBY BUILDING SYSTEMS INC (View Classification) — "Kirby-Rib II"


    MARLYN METALS INC (View Classification) — "R" or "PBR"


    MBCI (View Classification) — "R" or "PBR" Panel


    MCELROY METAL MILL INC (View Classification) — "R" Panel


    MESCO METAL BUILDINGS (View Classification) — "R" or "PBR" Panel


    METALLION INDUSTRIES INC (View Classification) — "PBR"


    NCI BUILDING SYSTEMS L P (View Classification) — "R" or "PBR" Panel


    NORTHLAND STEEL AND TRIM (View Classification) — "R-Panel"


    NUCOR BUILDING SYSTEMS, DIV OF NUCOR CORP (View Classification) — "Classic" Panel


    OAKLAND METAL BUILDINGS INC (View Classification) — "PBR"


    PRIME BUILDING COMPONENTS L L C (View Classification) — "R Panel"


    RAMCO BUILDER AND SUPPLY LLC — "R-Panel"


    RIGID GLOBAL BUILDINGS L L C (View Classification) — "R" or "PBR"


    ROYAL METAL BUILDING COMPONENTS (View Classification) — "Royal Span" or "Royal Span X"


    MUELLER INC (View Classification) — "R" or "PBR"


    SAN ANTONIO QUALITY METALS (View Classification) — "PBR-Panel"


    SBC BUILDING SYSTEMS L L C (View Classification) — "SBC PBR Panel"


    SCHULTE BUILDING SYSTEMS INC (View Classification) — "R" or "PBR" Panel


    SOUTHWEST METAL COMPONENTS AND SUPPLY LP (View Classification) — "R-Panel" or "PBR"


    STANDARD STRUCTURES INC (View Classification) — "PBR Panel" or "R Panel"


    STEEL BUILDING SUPPLY INC (View Classification) — "R" or "PBR" Panel


    TAYLOR & SONS PIPE & STEEL INC (View Classification) — "R-Panel"


    TERRY BUILDING CO INC (View Classification) — "R" Panel


    TEXAS BUILDING AND ROOFING SUPPLIES INC — "R" or "PBR" Panel


    TREMCO INC — "TremLock "R" Panel"


    TSB INDUSTRIAL INC (View Classification) — "R" Panel.


    UNION CORRUGATING CO (View Classification) — "R-Panel" or "PBR-Panel"


    UNITED STRUCTURES OF AMERICA INC (View Classification) — "U.S.A.R"


    WEST TEXAS STEEL & SUPPLY (View Classification) — "R" or "PBR"


    WHEELER METALS INC (View Classification) — "R-Panel"


    WHIRLWIND STEEL BUILDINGS INC (View Classification) — "Superspan"


    1A. Metal Roof Deck Panels* — (not shown) No. 26 MSG minimum gauge coated steel. Panels continuous over two or more spans. End laps to occur over purlins with panels overlapped minimum 4 in. to maximum 6 in. with laps beginning even with purlin web and extending across purlin flange. A bead of sealant may be used at panel side and end laps.

    WHIRLWIND STEEL BUILDINGS INC (View Classification) — "Superspan"


    2. Building Units* — Translucent, reinforced plastic panels. Thickness 1/16 in. formed to the same configuration as the metal roof deck panels. Also, 1/32- in thick translucent polycarbonate plastic panels as noted below, formed to the same configuration as the metal roof deck panels. Panels continuous over two spans.

    ACI BUILDING SYSTEMS INC (View Classification) — "R Skylight"


    ALLIANCE STEEL INC (View Classification) — "Type Skylight"


    ALL STEEL BUILDINGS & COMPONENTS TUBULAR DIVISION INC (View Classification) — "R or PBR panel"


    AMERICAN BUILDINGS CO (View Classification) — Long Span III Skylight


    B C STEEL BUILDINGS INC (View Classification) — "B Panel Skylight"


    HORIZON STRUCTURAL SYSTEMS (View Classification) — "PBR Skylight"


    KIRBY BUILDING SYSTEMS INC (View Classification) — "Kirby-Rib II Skylite Panels"


    MCELROY METAL MILL INC (View Classification) — "R Skylight"


    NCI BUILDING SYSTEMS L P (View Classification) — "R" Light Transmiting Panel


    NUCOR BUILDING SYSTEMS, DIV OF NUCOR CORP (View Classification) — "Classic"


    MUELLER INC (View Classification) — "R Skylight"


    SCHULTE BUILDING SYSTEMS INC (View Classification) — "ACRYLIT"


    UNITED STRUCTURES OF AMERICA INC (View Classification) — "U.S.A. R Skylight"


    WHIRLWIND STEEL BUILDINGS INC (View Classification) — "Superspan Skylight"


    3. Panel Fasteners — For steel panel to purlin and for translucent panel to purlin connections to be No. 12-14 by 1 in. self-drilling, self-tapping, hex head, plated steel screws with a separate or integral 9/16 in. to 5/8 in. O.D. formed steel or combination zinc and steel washer and a neoprene/EPDM sealing washer. Fasteners for panel connections to be same type and length.

    Fastener for panel to purlin connection to be 1-1/4 or 1-1/2 in. long when insulation (Item 6) is greater than 4-1/2 in.

    Spacing — For steel panel to purlin fasteners, spacing to be 12 in. on center beginning 2-1/2 in. from the center line on one side of each major rib.

    Spacing at end lap to be in a 5-7-5-7 in. pattern beginning 2 1/2 in. from the center line on both sides of each major rib.

    For translucent panel — to — purlin fasteners, spacing to be in a 5, 3 1/2, 3 1/2, 5 in. pattern beginning 2 1/2 in. from the center line on both sides of each major rib.

    For steel panel — to — panel fasteners, spacing to be 20 in. on center. For translucent panel — to — steel panel fasteners, spacing to be 12 in. on center driven into rib reinforcement (Item 4).

    4. Translucent Panel Rib Reinforcement — For side support — hat — shaped section fabricated from No. 26 MSG steel to the configuration of the steel panel major rib.
    5. Translucent Panel Purlin Reinforcement — For translucent panel reinforcement over purlins, 3 in. wide by No. 26 MSG thick steel strips fabricated in the shape of the metal panel.
    6. Insulation — (Optional) — Any compressible blanket insulation 6 in. maximum thickness before compression.
    7. Purlins — No. 16 MSG minimum gauge steel (50,000 psi minimum yield strength).
    8. Lateral Bracing — Not shown. As required.

    Refer to general information, Roof Deck Constructions, (On-Line Certification Directory) for items not evaluated.

    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2018-11-08
TGKX.167 167 TGKX P1557786 CONSTRUCTION Active 20181108 20181108 650404001 201077001 103959001 121975001 100584108 595691001 189626001 640561001 347953002 100590804 100506410 920304001 100515071 100579824 157261001 960510002 P759575 676209002 100124271 P893568 100057479 P1362312 111287001 100607124 134264001 100576058 129210001 100405624 P1759028 100556627 P1440218 467600006 113651001 139289001 513628001 518549001 P830020 901683001 P1279971 385127001 100013528 753882001 P1619395 100570336 889152001 P1632849 100560333 P1523982 100604030 105578001 158538001 637483001 100521107 100607781 100535089 718947007 P1557786 921539001 771112001 P2227950 100539719 160466001 160466001 201077001 121975001 103959001 189626001 640561001 100576058 467600006 513628001 901683001 385127001 P1632849 100604030 771112001 160466001

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".