UL PRODUCT CATEGORY

Roofing Systems, Uplift Resistance


See General Information for Roofing Systems, Uplift Resistance

ROCKWOOLR14138
8024 ESQUESING LINE
MILTON, ON L9T 6W3 CANADA

SINGLE PLY MEMBRANE SYSTEMS - ADHERED

Optional text describing the following items:

1. Uplift Resistance — -90 psf.
Deck: — Steel, minimum 22 MSG. and minimum yield strength 40 ksi.
Insulation: — Minimum 2-inch thick Atlas Roofing Corp. "AC Foam II", Firestone Building Products Co. LLC "ISO 95+ GL", Hunter Panels "H-Shield", GAF "EnergyGuard Polyiso Insulation", Johns Manville "ENRGY 3" or Rmax LTD "Multi-Max FA3", mechanically fastened through the top layer into the steel deck.
Fasteners: — OMG "Roofgrip #14" or "OMG HD" with "OMG 3 in. Galvalume Steel Plate", SFS Intec "Dekfast 14" with "Dekfast 3" Round Steel Plate" or Altenloh, Brinck & Co. "TRUFAST #14 HD Fastener" with "TRUFAST 3" Metal Insulation Plate" at 1 per 2 ft.2 or 16 parts per 4x8 ft board or 8 parts per 4x4 ft board.
Insulation (Optional): — Minimum 1-inch thick Atlas Roofing Corp. "AC Foam II", Firestone Building Products Co. LLC "ISO 95+ GL", Hunter Panels "H-Shield", GAF "EnergyGuard Polyiso Insulation", Johns Manville "ENRGY 3" or Rmax LTD "Multi-Max FA3", adhered in continuous ribbons with ICP Adhesives & Sealants "ICP CR-20", OMG "OlyBond 500" or Royal Adhesives & Sealants "Millennium One Step Foamable Adhesive" or "Millennium PG-1 Pump Grade Adhesive", maximum 12 inches o.c.
Insulation: — Minimum 2-inch thick ROCKWOOL "Multifix" adhered in continuous ribbons with ICP Adhesives & Sealants "ICP CR-20", OMG "OlyBond 500" or Royal Adhesives & Sealants "Millennium One Step Foamable Adhesive" or "Millennium PG-1 Pump Grade Adhesive", maximum 12 inches o.c.
Membrane: — GAF "EverGuard TPO" fully adhered at a rate of 2 gal./100-ft.2 with "EverGuard Low VOC TPO Bonding Adhesive", "EverGuard TPO #1121", "EverGuard TPO 3 Square" or "EverGuard WB 181", or GAF "EverGuard TPO FB Ultra" fully adhered at a rate of 2 gal./100-ft.2 with "EverGuard WB 181" or spatter applied with "GAF 2-Part Roofing Adhesive"; or Seaman Corporation "FiberTite", "FiberTite SM", "FiberTite XT" or "FiberTite Xtreme" fully adhered at a rate of 2 gal./100-ft.2 with "FTR 190e", or "FiberTite SM" or "FiberTite Xtreme" fully adhered at a rate of 2 gal./100-ft.2 with "FTR 490", or "FiberTite FB" fully adhered at a rate of 2 gal./100-ft.2 with "FTR 290", "FTR 390", "FTR 490" at a rate of 2 gal./100-ft.2, or spatter applied with ICP Adhesives & Sealants "ICP CR-20"; Sika Sarnafil "G410", "S327" or "Sikaplan Adhered" fully adhered at a rate of 2 gal./100-ft.2 with "Sarnacol 2121", "Sarnacol 2170" or "Sarnacol 2170 VC", or Sika Sarnafil "Sikaplan Adhered" fully adhered at a rate of 2 gal./100-ft.2 with "Sikaplan Single-Step Membrane Adhesive", or Sika Sarnafil "G410 Feltback", "S327 Feltback" or "Sikaplan Adhered Feltback" fully adhered at a rate of 2 gal./100-ft.2 with "Sarnacol 2121", "Sarnacol 2170" or "Sarnacol 2170 VC", or Sika Sarnafil "Sikaplan Adhered Feltback" fully adhered at a rate of 2 gal./100-ft.2 with "Sikaplan Single-Step Membrane Adhesive".

 

Click here to view the ICC-ES Evaluation Report, authorized by ICC-ES and provided for your convenience.

The ICC-ES Mark is issued by ICC-ES, and ICC-ES is solely responsible for making the decision to certify a product for an ICC-ES Evaluation Report. UL is not responsible for the availability of the linked ICC-ES website or its content, and UL makes no warranty, representation, or guarantee as to the accuracy, timeliness, or completeness of the information contained therein. UL disclaims any liability for the availability of or content on the linked ICC-ES website and reliance by any person or entity on the information contained therein. All records pertaining to ICC-ES Evaluation Reports are maintained solely by ICC-ES. Visit www.icc-es.org for a complete list of products bearing ICC-ES certification.

Last Updated on 2018-08-23
TGIK.R14138 R14138 TGIK P1798035 LISTING Active 20180823 20180823

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".