UL PRODUCT CATEGORY

[Elevator Equipment for Use in Hazardous Locations] Elevator Control Panels for Use in Hazardous Locations, FSNA


See General Information for Elevator Equipment for Use in Hazardous Locations

USE

This category covers elevator control panels consisting of assemblies of equipment intended to control elevators, dumbwaiters, escalators, moving walks, inclined lifts, and their associated equipment.

PRODUCT IDENTITY

The following product identity appears on the product:

    Elevator Control Panel for Use in Hazardous Locations

The words "Hazardous Locations" may be abbreviated "Haz. Loc." or "HazLoc."

RELATED PRODUCTS

See:

Elevator Control Panels Relating to Hazardous Locations (FSSA)
Industrial Control Panels and Assemblies for Use in Hazardous Locations (NNNY)
Industrial Control Panels Relating to Hazardous Locations (NRBX)

ADDITIONAL INFORMATION

For additional information, see Equipment for Use in and Relating to Class I, II and III, Division 1 and 2 Hazardous Locations (AAIZ).

REQUIREMENTS

The basic unclassified locations standard used to investigate products in this category is ANSI/UL 508A, "Industrial Control Panels."

The basic hazardous (classified) locations standards used to investigate products in this category are referenced in Equipment for Use in and Relating to Class I, II and III, Division 1 and 2 Hazardous Locations (AAIZ).

Where indicated in the individual certifications, elevator control panels have also been investigated to ANSI/ASME A17.1, "Safety Code for Elevators and Escalators," and ANSI/ASME A17.5, "Elevator and Escalator Electrical Equipment."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

AS TO ELECTRICAL SHOCK, EXPLOSION AND FIRE HAZARDS ONLY
Where indicated in the individual certifications, the Certification Mark will also include the statement:

ALSO CERTIFIED TO ANSI/ASME A17.1-(date) AND ANSI/ASME A17.5-(date)

Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

ELEVATOR CONTROL PANEL FOR USE IN HAZARDOUS LOCATIONS
AS TO ELECTRICAL SHOCK, EXPLOSION AND FIRE HAZARD ONLY
Issue No.

The words "HAZARDOUS LOCATIONS" may be abbreviated "HAZ. LOC." or "HAZLOC."

Where indicated in the individual Classifications, the Classification Mark will also include the statement:

ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/ASME A17.1-(date) AND ANSI/ASME A17.5-(date)

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Control Panels, Elevator, for Use in Hazardous Locations
Last Updated on 2018-08-24
FSNA.GuideInfo FSNA Active 20180824 20180824

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".