UL PRODUCT CATEGORY

Roofing Membranes, CHCI


Guide Information for Fire-resistance Ratings

1507.11

USE

This category covers roofing membranes investigated for use in fire-resistance designs as detailed in Fire-resistance Ratings - ANSI/UL 263 (BXUV). The single-ply roofing membranes (such as EPDM, PVC, CSPE, modified bitumen, etc.) are intended for use as the roof covering in roof-ceiling designs. The membranes have been investigated for use in specified designs when installed in accordance with the details described for each certified company.

Where indicated in the individual certifications, products covered under this category have also been evaluated by ICC Evaluation Service (ICC-ES).

PRODUCT IDENTITY

The following product identity appears on the product:

    Roofing Membrane

RELATED PRODUCTS

For information on related products, see Fire-resistance Ratings - ANSI/UL 263 (BXUV).

For information on external fire exposure, see Roofing Systems (TGFU).

ADDITIONAL INFORMATION

For additional information, see Fire-resistance Ratings (BXRH).

REQUIREMENTS

The basic standard used to investigate products in this category is ANSI/UL 263, "Fire Tests of Building Construction and Materials."

UL MARK

The Certification Mark of UL on the product or package of products is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

AS TO FIRE RESISTANCE
DESIGN NO(S). ____
SEE UL ONLINE CERTIFICATIONS DIRECTORY

or

AS TO FIRE RESISTANCE
SEE UL ONLINE CERTIFICATIONS DIRECTORY

Alternate UL Mark

The Classification Mark of UL on the packaging is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

ROOFING MEMBRANE
FIRE RESISTANCE CLASSIFICATION
DESIGN NO(S). ____
SEE UL FIRE RESISTANCE DIRECTORY
Control No.

or

ROOFING MEMBRANE
FIRE RESISTANCE CLASSIFICATION
SEE UL FIRE RESISTANCE DIRECTORY
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Membranes, RoofingMembranes, Single PlySingle-ply Membranes
Last Updated on 2013-05-16
CHCI.GuideInfo CHCI Active 20130516 20101005

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".