Design No. U654

October 20, 2017

Nonbearing Wall Rating - 1 HR

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

    1. Flashing Channels — 6 in. wide channels with 1-3/4 and 3 in. flanges, fabricated from 16 MSG thick galvanized or aluminum-zinc alloy coated sheet steel. Fastened to the frame with 1/4 in. by 1-3/4 in. long anchors spaced 16 in. OC.
    2. Interior Steel Liner — Panels available in various widths, fabricated from 24 MSG thick galvanized or aluminum-zinc alloy coated sheet steel. Fastened to flashing channels with 3/4 in. long sheet metal screws spaced 12 in. OC. Interlocking joints of adjacent panels sealed with factory-applied butyl caulking and secured with 3/4 in. long sheet metal screws spaced 12 in. OC. Butyl tape applied between the steel liner panels and the flashing channels to provide an air barrier.
    3. Z-Bar Sub-Girts — 6 in. wide notched z-bars with 1 and 1-1/2 in. flanges, fabricated from 18 MSG thick galvanized or aluminum-zinc alloy coated sheet steel. Spaced a max of 60 in. OC. Fastened to the steel liner panels with 3/4 in. long sheet metal screws spaced not more than 10 in. OC.
    4. Ceramic Fibre Blanket — 8 pcf density, 1/2 in. thick, min 4.0 in. wide, attached to the z-bar sub-girts with stick pins spaced 10 in. OC.
    5. Batts and Blankets* — Two layers of 6 pcf density mineral wool batts processed from rock and slag, 24 or 32 in. wide by 48 or 60 in. long by 3 in.thick, installed with joints staggered. The overall thickness of the wall may be increased provided the Mineral Fibre Insulation (item 5) is used to completely fill the wall cavity, and provided the size of the Flashing Channels (item 1) and Z-Bar Sub-Girts (item 3) are increased to match the thicker walls.

    ROCKWOOL MALAYSIA SDN BHD — Type Roxul FireWall 605


    ROCKWOOL — Type "Roxul Safe 65"


    THERMAFIBER INC — Type MetalGuard™ - 1 Hr.


    6. Exterior Cladding and Accessories — Corrugated panels, available in various profiles and widths, fabricated from 26 MSG thick galvanized or aluminum-zinc alloy coated sheet steel. Fastened to the z-bar sub-girts with 3/4 in. long sheet metal screws spaced 12 in. OC. Fastened to flashing channels with 3/4 in. long sheet metal screws spaced 16 in.OC. Side lap joints of adjacent panels fastened with 3/4 in. long sheet metal screws spaced 16 in. OC. The top and bottom of the exterior cladding are trimmed with cap and drip flashings respectively.

    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2017-10-20
BXUV.U654 U654 BXUV P1798035 DESIGN Active 20171020 20171020 116367001 P1798035 324198001

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".