Design No. U615

April 16, 2019

(Exposed to Fire on Interior Face only)

Nonbearing Wall Rating — 2 HR.

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Alternate Construction
    1. Supporting Angles — 3 by 3 by 1/4 in. steel, attached to masonry with steel expansion shields and 3/8 in. diam by 2 in. long steel bolts spaced 24 in. O.C.
    2. Flashing Angles — 2 by 3 in., 18 MSG metal coated steel, 2-in. leg attached to masonry or wall with 1-1/2 in.-14 hex head steel sheet metal screws and inserts spaced 18 in. OC.
    3. Wall and Partition Facings and Accessories*— Steel Liners — 12 or 24 in. wide channel shaped min 18 MSG steel units attached to supporting and flashing angles with 3/4 in.-12 hex head self-tapping steel screws with combination steel and neoprene washers, spaced 12 in. OC at supporting angles (three screws at each end for 24 in. wide liners and two screws at each end for 12 in. wide liners) and 18 in. OC along flashing angles.

    CENTRIA, A DIVISION OF NCI GROUP, INCType F-1E, F-4E, L-1, L-1V, L-2 or L-2V.


    4. Sub-girts — Hat shaped sub-girts, 3/8 in. deep by 2-5/8 in. wide with 11/16 in legs, 16 MSG metal coated steel attached to lip of liners along both legs with 1-1/8 in.-12 hex washer head self-tapping, self-drilling steel screws. Sub-girts spaced vertically not more than 48 in. OC with top and bottom sub-girts located not more than 3 in. from supporting angles.
    5. Batts and Blankets* — 1-1/2 in. thick wool or glass fiber batts. Installed in liner cavities with horizontal joints in adjacent cavities staggered.

    CERTAINTEED CORP

    JOHNS MANVILLE

    KNAUF INSULATION LLC

    MANSON INSULATION INC

    OWENS CORNING

    ROCKWOOLType AFB


    6. Gypsum Board* — 5/8 in. thick by 48 in. wide sheets, three layers applied vertically, vertical and horizontal joints between adjacent layers staggered. First and second layers attached to sub-girts with 0.115 in. diam by 1-5/8 in. long self-drilling, self-tapping bugle head steel screws located alternately 12 in. from the edges of each board. Third layer attached to first and second layers with 1-1/2 in.-10 double lead bugle head steel screws spaced vertically 24 in. OC and alternately 12 in. from the edges of each board.

    CABOT MANUFACTURING ULCType X, 5/8 Type X, Type Blueglass Exterior Sheathing


    AMERICAN GYPSUM CO Type AGX-1, M-Glass, AG-C, LightRoc.


    BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO Type DBX-1.


    CERTAINTEED GYPSUM INCTypes EGRG, GlasRoc, GlasRoc-2, Type C, Type X, Type X-1, Easi-Lite Type X-2, SilentFX, 5/8" Easi-Lite Type X.


    CGC INCTypes IP-X1, SCX, SHX, ULX, USGX, WRX.


    CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L CTypes LGFC2A, LGFC6A, LGFC-C/A, LGFC-WD, LGLLX, CLLX.


    GEORGIA-PACIFIC GYPSUM L L CType 5, C, DAPC, TG-C, Type X, Veneer Plaster Base-Type X, Water Rated-Type X, Sheathing Type-X, Soffit-Type X, Type X ComfortGuard Sound Deadening Board, Type LWX, Veneer Plaster Base-Type LWX, Water Rated-Type LWX, Sheathing Type-LWX, Soffit-Type LWX, Type DGLW, Water Rated-Type DGLW, Sheathing Type- DGLW, Soffit-Type DGLW, Type LW2X, Veneer Plaster Base - Type LW2X, Water Rated - Type LW2X, Sheathing - Type LW2X, Soffit - Type LW2X, Type DGL2W, Water Rated - Type DGL2W, Sheathing - Type DGL2W, Type DGG, Type DAP, Type DS.


    NATIONAL GYPSUM COTypes FSK, FSMR-C, FSW, FSW-3, FSW-8, FSL.


    NATIONAL GYPSUM CORiyadh, Saudi Arabia — Type FR, or WR.


    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUMTypes PG-11, PGS-WRS.


    SAINT-GOBAIN GYPROC MIDDLE EAST FZE Type Gyproc FireStop, Gyproc FireStop MR, Gyproc FireStop M2TECH, Gyproc FireStop ACTIV'Air, Gyproc FireStop MR ACTIV'Air, Gyproc FireStop M2TECH ACTIV'Air, Gyproc DuraLine, Gyproc DuraLine MR, Gyproc DuraLine M2TECH, Gyproc DuraLine ACTIV'Air, Gyproc DuraLine MR ACTIV'Air, Gyproc DuraLine M2TECH ACTIV'Air


    SIAM GYPSUM INDUSTRY (SARABURI) CO LTDType EX-1


    THAI GYPSUM PRODUCTS PCL Type C, Type X.


    UNITED STATES GYPSUM COTypes FRX-G, IP-X1, SCX, SHX, ULX, WRX, USGX, ULIX


    USG BORAL DRYWALL SFZ LLCType SCX, USGX


    USG MEXICO S A DE C VTypes IP-X1, SCX, SHX, ULX, USGX or WRX.


    6A. Gypsum Board* — As an alternate to Item 6 — Nom 3/4 in. thick, 48 in. wide, installed as described in Item 6 with length of fasteners for second layer increased to 2-1/4 in.

    CGC INCType AR.


    UNITED STATES GYPSUM COType AR.


    USG MEXICO S A DE C VType AR.


    6B. Gypsum Board* — (As an alternate to Items 6 and 6A) — Nominal 5/8 in. thick, 4 ft wide panels, secured as described in Item 6.

    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUMType QuietRock ES.


    6C. Wall and Partition Facings and Accessories* — (As an alternate to Items 6 through 6B) — Composite Gypsum Panel — Nominal 5/8 in. thick, 4 ft wide panels, secured as described in Item 6.

    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUMType QuietRock 527.


    7. Sub-girts — Channel or hat shaped, 14 or 16 MSG metal coated steel. Channel sub-girts, 14 MSG, 7/16 in. deep by 1-5/16 in. wide with 5/16 in. flanges; 1/8 by 3/16 in. rectangular tabs spaced 12 in. OC punched in face of channel. Hat shaped sub-girts, 16 MSG, 3/8 in. deep by 2-5/8 in. wide with 11/16 in. legs. Sub-girts placed over wallboard and attached to sub-girts on opposite side (Item 4) with 2-1/2 in.-12 hex washer head self-drilling, self-tapping steel screws spaced horizontally 24 in. OC.
    8. Bottom Flashing Angle — 4 by 2-1/2 in. 18 MSG aluminum or 22 MSG metal coated steel, 4 in. leg attached in position with bottom sub-girt. For protected metal facing units, bottom flashing 2 by 4 in. angle, 18 MSG protected steel.
    9. Connecting Angle — 1-1/2 by 1-1/2 in., 18 MSG aluminum or 22 MSG metal coated steel, used to connect zee-shaped flashing to facing units, attached to masonry or wall with 1-1/2 in.-14 hex head steel sheet metal screws and inserts spaced 18 in. OC.
    10. Flashing Angles — 1-1/2 by 1-1/2 in. angle and 2 by 1-1/2 by 1-1/2 in. zee-shaped angle, 18 MSG aluminum or 22 MSG metal coated steel, attached to facing units and connecting angle with 3/4 in.-12 hex head steel sheet metal screws spaced vertically 18 in. OC, 1-1/2 by 1-1/2 in. angle attached to masonry or wall with 1-1/2 in.-14 hex head steel sheet metal screws and inserts spaced 18 in. OC or 2 by 6 in. protected metal flashing angles attached to protected metal facing units with 3/4 in.-12 hex head sheet metal screws spaced 12 in. OC.
    11. Closure Angles — 1-1/2 by 1-5/8 in., 18 MSG aluminum or 22 MSG metal coated steel, supplied in 5-7/8 in. lengths or 1-5/8 by 1-5/8 in. protected metal angle, 18 MSG steel. One leg of angle notched to fit contour of facing units, attached to facing units with 3/4 in.-12 hex head steel sheet metal screws spaced 12 in. OC.
    12. Top Flashing Angle — 2 by 2 in., 18 MSG aluminum or 22 MSG metal coated steel or 2 by 4 in. protected metal, 18 MSG steel, attached to facing units with 3/4 in.-12 hex head self-tapping steel screws spaced 12 in. OC and to ceiling with 1-1/2 in.-14 hex head self-tapping steel screws and inserts spaced 18 in. OC.
    13. Mullion — Hat shaped, 2-1/2 in. wide with 11/16 in. legs, 2-1/8 or 3-7/8 in. deep for 18 or 24 in. wide facing units respectively, 18 MSG metal coated steel. Mullions spaced 18 or 24 in. OC, attached to sub-girts with 3/4 in.-12 hex steel screws at each leg.
    14. End Mullion Flashing — Zee-shaped, 22 MSG metal coated steel or protected metal, or 16 MSG aluminum or porcelain-coated aluminum, 1-5/8 by 7/8 by 2 in. or 1-9/16 by 2-5/16 by 2-1/8 in. for the 18 and 24 in. facing units respectively, attached to the end mullion with spring clips and to the side flashing angles with self-tapping steel screws.
    15. Trim Cap — 2 in. wide, 18 MSG aluminum snapped on over spring clips attached to mullions.
    16. Top Closure Angle — 1-3/8 in. in height, 18 or 24 in. in length, shaped to fit curvature of facing units, 18 MSG aluminum or porcelain-coated aluminum, or 20 MSG metal coated steel, or protected metal attached to mullions with 3/4 in.-12 hex self-tapping screws.
    17. Top Flashing Angle — 2 by 4 in. angle, 22 MSG metal coated steel or protected metal, or 16 MSG aluminum or porcelain-coated aluminum, 2 in. leg attached to masonry with 1-3/4 in.-12 hex screws spaced 12 in. OC and 4 in. leg to mullions with 5/8 in.-12 hex screws.
    18. Side Flashing Angle — One leg 2 in. with other leg of sufficient length to accommodate spacing of end mullion, 22 MSG metal coated steel or protected metal, or 16 MSG aluminum or porcelain-coated aluminum, 2 in. leg attached to masonry or wall with 1-1/2 in.-14 hex head steel sheet metal screws and inserts spaced 18 in. O.C. and other leg to end mullion flashing with 3/4 in.-12 hex head steel sheet metal screws spaced 18 in. O.C.

    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2019-04-16
BXUV.U615 U615 BXUV 128669004 DESIGN Active 20190416 20190416 128669004 261742029 880051001 105439005 777331002 334053001 100562937 283066001 736720001 100219806 846414005 299592001 294450001 923830002 100046076 798029001 100584219 730408054 287840003 846414005 730408054 287840003 103326001 P1798035 P1802957 100572141

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".