Design No. U495

June 14, 2019

Nonbearing Wall Rating — 1 or 2 Hr.

(See Items 5 and 7)

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

    1. Floor and Ceiling Runners — (Not Shown) — Channel-shaped runners, 3-5/8 in. wide (min), 1-1/4 in. legs, formed from No. 25 MSG (min) galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC, max.
    1A. Framing Members* — Floor and Ceiling Runners — Not Shown — In lieu of Item 1 — For use with Item 2A, proprietary channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max.

    CALIFORNIA EXPANDED METAL PRODUCTS COViper20™ Track


    MARINO/WARE, DIV OF WARE INDUSTRIES INCViper20™ Track


    FUSION BUILDING PRODUCTSViper20™ Track


    IMPERIAL MANUFACTURING GROUP INCViper20™ Track


    1B. Framing Members* — Floor and Ceiling Runners — Not Shown — In lieu of Item 1 — For use with Item 2B, channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max.

    CLARKDIETRICH BUILDING SYSTEMSCD ProTRAK


    DMFCWBS L L CProTRAK


    MBA METAL FRAMINGProTRAK


    RAM SALES L L CRam ProTRAK


    STEEL STRUCTURAL PRODUCTS L L CTri-S ProTRAK


    1C. Framing Members* — Floor and Ceiling Runners — Not Shown — In lieu of Item 1 — For use with Item 2C, proprietary channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max.

    TELLING INDUSTRIES L L CViper20™ Track


    1D. Framing Members* — Floor and Ceiling Runners — Not Shown — In lieu of Item 1 — For use with Item 2D, channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max.

    TELLING INDUSTRIES L L CTRUE-TRACK™


    1E. Framing Members* — Floor and Ceiling Runners — Not Shown — In lieu of Item 1 — For use with Item 2F, channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max.

    STEEL INVESTMENT GROUP L L CAlphaTRAK


    2. Steel Studs — Channel-shaped 3-5/8 in. wide (min), 1-1/4 in. legs, 3/8 in. folded back returns, formed from No. 25 MSG (min) galv steel, spaced 24 in. OC max.
    2A. Framing Members* — Steel Studs — Not Shown — In lieu of Item 2 — For use with Item 1A, proprietary channel shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max.

    CALIFORNIA EXPANDED METAL PRODUCTS COViper20™


    MARINO/WARE, DIV OF WARE INDUSTRIES INCViper20™


    FUSION BUILDING PRODUCTSViper20™


    IMPERIAL MANUFACTURING GROUP INCViper20™


    2B. Framing Members* — Steel Studs — Not Shown — In lieu of Item 2 — For use with Item 1B, channel shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max.

    CLARKDIETRICH BUILDING SYSTEMSCD ProSTUD


    DMFCWBS L L CProSTUD


    MBA METAL FRAMINGProSTUD


    RAM SALES L L CRam ProSTUD


    STEEL STRUCTURAL PRODUCTS L L CTri-S ProSTUD


    2C. Framing Members* — Steel Studs — Not Shown — In lieu of Item 2 — For use with Item 1C, proprietary channel shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max.

    TELLING INDUSTRIES L L CViper20™


    2D. Framing Members* — Steel Studs — Not Shown — In lieu of Item 2 — For use with Item 1D, channel shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max.

    TELLING INDUSTRIES L L CTRUE-STUD™


    2E. Framing Members* — Steel Studs — As an alternate to Item 2 — For use with Item 1A (3-5/8 in. wide track), channel shaped studs, fabricated from min 25 MSG corrosion-protected steel, 1-1/4 in. wide by 3-5/8 in. deep, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height.

    MARINO/WARE, DIV OF WARE INDUSTRIES INCStudRite™


    2F. Framing Members* — Steel Studs — Not Shown — In lieu of Item 2 — For use with Item 1E, channel shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max.

    STEEL INVESTMENT GROUP L L CAlphaSTUD


    3. Batts and Blankets* — (Optional, Not Shown) — Mineral wool or glass fiber batts partially or completely filling stud cavity.

    See Batts and Blankets (BZJZ) category for names of Classified companies.

    3A. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 3) — (100% Borate Formulation) — Spray applied cellulose material. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product with a nominal dry density of 2.7 lb/ft3. Alternate Application Method: The fiber is applied without water or adhesive at a nominal dry density of 3.5 lb/ft3, in accordance with the application instructions supplied with the product.

    U S GREENFIBER L L CINS735 & INS745 for use with wet or dry application. INS765LD and INS770LD are to be used for dry application only.


    3B. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 3) - Spray applied cellulose insulation material. The fiber is applied with water to interior surfaces in accordance with the application instructions supplied with the product. Applied to completely fill the enclosed cavity. Minimum dry density of 4.3 pounds per cubic ft.

    NU-WOOL CO INC Cellulose Insulation


    3C. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 3) — Spray applied cellulose fiber. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product. The minimum dry density shall be 4.30 lbs/ft3.

    INTERNATIONAL CELLULOSE CORPCelbar-RL


    3D. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 3) — Spray applied cellulose material. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product. To facilitate the installation of the material, any thin, woven or non-woven netting may be attached by any means possible to the outer face the studs. The material shall reach equilibrium moisture content before the installation of materials on either face of the studs. The minimum dry density shall be 5.79 lbs/ft3.

    APPLEGATE HOLDINGS L L CApplegate Advanced Stabilized Cellulose Insulation


    4. Screws — Type S self-tapping screws, 1-1/4 or 2 in. long, (1 Hr) and 2-1/2 in. long (2 Hr).
    5. Building Units* — For 1 Hr Rating — Nom 5/8 or 3/4 in. thick, 4 ft wide, faced gypsum board panels with the faced side on the interior wall cavity. Panels attached to studs and floor and ceiling runners with screws spaced 8 in. OC along the edges of the panel and 12 in. OC in the field of the panel. Joints oriented vertically and staggered on opposite sides of the assembly.

    MOMENTIVE PERFORMANCE MATERIALSType CoreGuard.


    6. Joint Tape and Compound — (Not Shown) — Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, 2 in. wide, embedded in first layer of compound over all joints.
    7. Gypsum Board* — For 2 Hr RatingAny 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom. 5/8 in. thick, 4 ft wide, gypsum board applied over exterior face of Building Unit (Item 5). Gypsum board to be applied vertically with joints staggered 24 in. from Building Unit (Item 5) and attached to studs and floor and ceiling runners with screws spaced 8 in. OC.

    CABOT MANUFACTURING ULC (View Classification)CKNX.R25370


    AMERICAN GYPSUM CO (View Classification)CKNX.R14196


    BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO (View Classification)CKNX.R19374


    CERTAINTEED GYPSUM INC (View Classification)CKNX.R3660


    CGC INC (View Classification)CKNX.R19751


    CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C (View Classification)CKNX.R18482


    GEORGIA-PACIFIC GYPSUM L L C (View Classification)CKNX.R2717


    GEORGIA-PACIFIC GYPSUM L L C (View Classification)CKNX.R6937


    LOADMASTER SYSTEMS INC (View Classification)CKNX.R11809


    NATIONAL GYPSUM CO (View Classification)CKNX.R3501


    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM (View Classification)CKNX.R7094


    PANEL REY S A (View Classification)CKNX.R21796


    SIAM GYPSUM INDUSTRY (SARABURI) CO LTD (View Classification)CKNX.R19262


    THAI GYPSUM PRODUCTS PCL (View Classification)CKNX.R27517


    UNITED STATES GYPSUM CO (View Classification)CKNX.R1319


    USG MEXICO S A DE C V (View Classification)CKNX.R16089


    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2019-06-14
BXUV.U495 U495 BXUV 157431003 DESIGN Active 20190614 20190614 100039004 980447001 P1823606 100567625 100570268 100530754 100557430 100593062 100581840 100512119 100512119 P1662204 100039004 980447001 P1823606 100567625 100570268 100530754 100557430 100593062 100581840 100512119 100512119 980447001 P1662204 184866001 882208001 979414001 123185001 157431003 100562937 283066001 736720001 100219806 846414005 294450001 299592001 413492002 226521001 923830002 100046076 544217001 798029001 100584219 730408054 287840003

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".