Design No. U332

October 10, 2017

Bearing Wall Rating — 1 Hr.

Nonbearing Wall Rating — 2 Hr.

Finish Rating — 23 Min.

This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

    1. Wood Studs — Nominal 2 by 4 in. spaced 16 in. OC effectively firestopped.
    2. Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom. 5/8 in. thick gypsum board applied horizontally or vertically, unless specified below, with beveled, square or tapered edges. Gypsum board nailed to studs and plates with 8d coated nails spaced 8 in. OC. All joints staggered 2 ft with joints on opposite side of wall.

    When used in widths other than 48 in., gypsum board to be installed horizontally.

    ACADIA DRYWALL SUPPLIES LTD (View Classification) — CKNX.R25370


    AMERICAN GYPSUM CO (View Classification) — CKNX.R14196


    BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO (View Classification) — CKNX.R19374


    CERTAINTEED GYPSUM INC (View Classification) — CKNX.R3660


    CGC INC (View Classification) — CKNX.R19751


    CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C (View Classification) — CKNX.R18482


    GEORGIA-PACIFIC GYPSUM L L C (View Classification) — CKNX.R2717


    LOADMASTER SYSTEMS INC (View Classification) — CKNX.R11809


    NATIONAL GYPSUM CO (View Classification) — CKNX.R3501


    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM (View Classification) — CKNX.R7094


    PANEL REY S A (View Classification) — CKNX.R21796


    SIAM GYPSUM INDUSTRY (SARABURI) CO LTD (View Classification) — CKNX.R19262


    THAI GYPSUM PRODUCTS PCL (View Classification) — CKNX.R27517


    UNITED STATES GYPSUM CO (View Classification) — CKNX.R1319


    USG BORAL DRYWALL SFZ LLC (View Classification) — CKNX.R38438


    USG MEXICO S A DE C V (View Classification) — CKNX.R16089


    2A. Gypsum Board* — (As an Alternate to Item 2) - 5/8 in. thick applied either horizontally or vertically. Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread gypsum panel steel screws spaced a max 8 in. OC, with last screw 1 in. from edge of board. When used in widths other than 48 in., gypsum board to be installed horizontally. All joints in face layers staggered with joints in base layers. Joints of each base layer offset with joints of base layer on opposite side.

    AMERICAN GYPSUM CO — Type AG-C.


    NATIONAL GYPSUM CO — Type FSK, Type FSK-G, Type FSW, Type FSW-3, Type FSW-5, Type FSW-G, Type FSK-C, Type FSW-C, Type FSMR-C, Type FSW-6, Type FSL


    2B. Gypsum Board* — (As an alternate to Items 2, and 2A) — 5/8 in. thick gypsum panels, with square edges, applied either horizontally or vertically. Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread gypsum panel steel screws spaced a max 8 in. OC, with last 2 screws 1 and 4 in. from edge of board or nailed as described in Item 2. When used in widths of other than 48 in., gypsum boards are to be installed horizontally.

    GEORGIA-PACIFIC GYPSUM L L C — Type DGG, GreenGlass Type X.


    2C. Gypsum Board* — (As an alternate to Items 2, 2A, and 2B) - 5/8 in. thick, 4 ft. wide, paper surfaced applied vertically only and secured as described in Item 2.

    GEORGIA-PACIFIC GYPSUM L L C — Type X ComfortGuard Sound Deadening Gypsum Board.


    2D. Gypsum Board* — (As an alternate to Items 2 through 2C) - 5/8 in. thick, 4 ft. wide, paper surfaced, applied vertically and fastened to the studs and plates with 6d cement coated nails 1-7/8 in. long, 0.0915 in. shank diam and 1/4 in. diam heads, 7 in. OC.

    NATIONAL GYPSUM CO — SoundBreak XP Type X Gypsum Board


    2E. Gypsum Board* — (As an alternate to Items 2 through 2D) — Nominal 5/8 in. thick, 4 ft wide panels, applied vertically and secured as described in Item 2.

    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock ES.


    2F. Gypsum Board* — (As an alternate to Items 2 through 2E) - 5/8 in. thick, 4 ft. wide, paper surfaced, applied vertically or horizontally and fastened to the studs per Item 2 or with 1-1/4 in. long Type W coarse thread gypsum panel steel screws spaced a max 8 in. OC, with last screw 1 in. from edge of board.

    CERTAINTEED GYPSUM INC — Type SilentFX


    2G. Wall and Partition Facings and Accessories* — (As an alternate to Items 2 through 2F) — Nominal 5/8 in. thick, 4 ft wide panels, applied vertically and secured as described in Item 2.

    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock 527.


    2H. Gypsum Board* — (As an alternate to Items 2) — 5/8 in. thick gypsum panels, with beveled, square, or tapered edges, applied either horizontally or vertically. Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread gypsum panel steel screws spaced a maximum 10 in. OC with the last two screws 4 and 1 in. from the edges of the board. When used in widths other than 48 in., gypsum panels are to be installed horizontally.

    CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC6A (finish rating 21 min), Type LGFC2A, Type LGFC-C/A, Type LGFC-WD, Type LGLLX


    3. Spray-Applied Fire Resistive Materials* — Sprayed with Type A-23 Adhesive in accordance with application instructions. The material is sprayed to completely fill the stud cavity. For wall assemblies having a fire rating of 1 hr, the fiber thickness may be reduced to 2 in. Minimum avg dry density of 11.0 pcf and a min ind density of 10.0 pcf. For method of density determination, refer to Design Information Section.

    AMERICAN SPRAYED FIBERS INC — Type DDM.


    4. Nails — 8d coated, 2-3/8 in. long. 0.113 in. shank diameter 1/4 in. diameter heads, spaced 8 in. OC.
    5. Joints and Nailheads — (Not shown) — Gypsum board joints covered with tape and joint compound. Nailheads covered with joint compound.

    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2017-10-10
BXUV.U332 U332 BXUV 923830002 DESIGN Active 20171010 20171010 100562937 283066001 736720001 100219806 846414005 294450001 299592001 226521001 923830002 100046076 544217001 798029001 100584219 730408054 P1802957 287840003 283066001 923830002 299592001 299592001 923830002 100046076 100219806 100046076 294450001 715603001

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC".