Design No. U320

March 06, 2018

Nonbearing Wall Rating — 1-1/2 HR.

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

    1. Wood Studs and End Plates — Nominally 2 by 4 in., studs spaced 16 in. OC in each row with studs in opposite rows staggered 8 in. OC. Effectively fire stopped at top and bottom of wall.
    2. Gypsum Sheathing — Regular 1/2 in. thick, two layers, 4 ft wide, one layer attached vertically to interior of each stud row with 1-1/2 in. long barbed 4d cement coated box nails spaced vertically 12 in. OC. Vertical joints in adjacent layers staggered 24 in.
    3. Gypsum Board* — 1/2 in. thick, 4 ft wide. Gypsum board nailed vertically to studs with 1-1/2 in. long annular ring 4d cement coated nails spaced vertically 7 in. OC.

    When Steel Framing Members* (Item 6-6C) are used, gypsum board attached to furring channels with 1 in. long Type S bugle-head steel screws spaced 12 in. OC.

    ACADIA DRYWALL SUPPLIES LTD — Type C


    AMERICAN GYPSUM CO — Types AG-C.


    CERTAINTEED GYPSUM INC — Type FRPC, Type C.


    CGC INC — Types C, IP-X2, IPC-AR.


    CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC-C/A.


    GEORGIA-PACIFIC GYPSUM L L C — Types 5, DAPC, TG-C.


    NATIONAL GYPSUM CO — Types FSK-C, FSW-C.


    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type PG-C.


    SAINT-GOBAIN GYPROC MIDDLE EAST FZE — Type Gyproc FireStop, Gyproc FireStop MR, Gyproc FireStop M2TECH, Gyproc FireStop ACTIV'Air, Gyproc FireStop MR ACTIV'Air, Gyproc FireStop M2TECH ACTIV'Air


    THAI GYPSUM PRODUCTS PCL — Type C.


    UNITED STATES GYPSUM CO — Types C, IP-X2, IPC-AR.


    USG BORAL DRYWALL SFZ LLC — Type C


    USG MEXICO S A DE C V — Types C, IP-X2, IPC-AR.


    3A. Gypsum Board* — (As an alternate to Item 3) — 1/2 in. thick, 4 ft wide. Gypsum board attached vertically to studs with 1-5/8 in. long wallboard screws spaced vertically 7 in. OC.

    When Steel Framing Members* (Item 6-6C) are used, gypsum board attached to furring channels with 1 in. long Type S bugle-head steel screws spaced 12 in. OC.

    NATIONAL GYPSUM CO — Type FSMR-C.


    3B. Gypsum Board* — (As an alternate to Item 3, 3A) — 5/8 in. thick, 4 ft wide. Gypsum board attached vertically to studs with 1-3/4 in. long wallboard screws spaced vertically 7 in. OC.

    When Steel Framing Members* (Item 6-6C) are used, gypsum board attached to furring channels with 1 in. long Type S bugle-head steel screws spaced 12 in. OC.

    NATIONAL GYPSUM CO — Type FSMR-C.


    4. Batts and Blankets* — 3 in. thick glass fiber or mineral wool batts, supplied in 15-in. widths installed to fill interior of stud cavities and friction held.

    CERTAINTEED CORP

    JOHNS MANVILLE

    KNAUF INSULATION LLC

    OWENS CORNING

    ROCKWOOL — Type AFB


    5. Finishing System — Gypsum board joints covered with paper tape and joint compound. Nailheads covered with joint compound. As an alternate, nom 3/32 in. thick gypsum veneer plaster may be applied to the entire surface of Classified veneer baseboard with joints reinforced with paper tape.
    6. Steel Framing Members* — (Optional, Not Shown) — Furring channels and Steel Framing Members as described below:
      a. Furring Channels — Formed of No. 25 MSG galv steel. 2-9/16 in. or 2-23/32 in. wide by 7/8 in. deep, spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Ends of adjoining channels are overlapped 6 in. and tied together with double strand of No. 18 SWG galv steel wire near each end of overlap. As an alternate, ends of adjoining channels may be overlapped 6 in. and secured together with two self-tapping #6 framing screws, min. 7/16 in. long at the midpoint of the overlap, with one screw on each flange of the channel. Gypsum board attached to furring channels as described in Item 3.
      b. Steel Framing Members* — Used to attach furring channels (Item a) to studs (Item 1). Clips spaced 48 in. OC., and secured to studs with No. 8 x 2-1/2 in. coarse drywall screw through the center grommet. Furring channels are friction fitted into clips. RSIC-1 clip for use with 2-9/16 in. wide furring channels. RSIC-1 (2.75) clip for use with 2-23/32 in. wide furring channels.
    6A. Steel Framing Members* — (Optional, Not Shown) — Furring channels and Steel Framing Members as described below:
      a. Furring Channels — Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Ends of adjoining channels are overlapped 6 in. and tied together with double strand of No. 18 SWG galv steel wire near each end of overlap. As an alternate, ends of adjoining channels may be overlapped 6 in. and secured together with two self-tapping #6 framing screws, min. 7/16 in. long at the midpoint of the overlap, with one screw on each flange of the channel. Gypsum board attached to furring channels as described in Item 3.
      b. Steel Framing Members* — Used to attach furring channels (Item a) to studs. Clips spaced 48 in. OC. Genie clips secured to studs with No. 8 x 1-1/2 in. coarse drywall screw through the center hole. Furring channels are friction fitted into clips.

      PLITEQ INC — Type Genie Clip


    6B. Steel Framing Members* — (Optional, Not Shown) — Furring channels and Steel Framing Members as described below:
      a. Furring Channels — Formed of No. 25 MSG galv steel. Spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Ends of adjoining channels overlapped 6 in. and tied together with double strand of No. 18 AWG galvanized steel wire.Gypsum board attached to furring channels as described in Item 3.
      b. Steel Framing Members* — Used to attach furring channels (Item 6Ba) to studs. Clips spaced 48 in. OC., and secured to studs with 2 in. coarse drywall screw with 1 in. diam washer through the center hole. Furring channels are friction fitted into clips.

      STUDCO BUILDING SYSTEMS — RESILMOUNT Sound Isolation Clips - Type A237R


    6C. Steel Framing Members* — (Optional, Not Shown) — Furring channels and Steel Framing Members as described below:
      A. Furring Channels — Formed of No. 25 MSG galv steel. Spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item 6Cb. Ends of adjoining channels overlapped 6 in. and tied together with double strand of No. 18 AWG galvanized steel wire. Gypsum board attached to furring channels as described in Item 3.
      B. Steel Framing Members* — Used to attach furring channels (Item 6Ca) to studs. Clips spaced 48 in. OC, and secured to studs with No. 8 x 2-1/2 in. coarse drywall screw through the center hole. Furring channels are friction fitted into clips.

      REGUPOL AMERICA — Type SonusClip


    7. Wall and Partition Facings and Accessories* — (Optional, Not Shown) — Nominal 1/2 in. thick, 4 ft wide panels, for optional use as an additional layer on one or both sides of the assembly. Panels attached in accordance with manufacturer's recommendations. When the QR-500 or QR-510 panel is installed between the wood framing and the UL Classified gypsum board, the required UL Classified gypsum board layer(s) is/are to be installed as indicated as to fastener type and spacing, except that the required fastener length shall be increased by a minimum of 1/2 in. Not evaluated or intended as a substitute for the required layer(s) of UL Classified Gypsum Board.

    PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock QR-500 and QR-510


    * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2018-03-06
BXUV.U320 U320 BXUV 923830002 DESIGN Active 20180306 20180306 283066001 100219806 846414005 299592001 294450001 923830002 100046076 100584219 730408054 287840003 923830002 923830002 261742029 880051001 105439005 334053001 100238497 100099348 103326001 100562937 P1798035 P1802957 100572141 P1642614

Design/System/Construction/Assembly Usage Disclaimer

  • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.
  • Authorities Having Jurisdiction should be consulted before construction.
  • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
  • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.
  • Only products which bear UL's Mark are considered Certified.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2018 UL LLC".